RSS Feed: TS-Si News Service. RSS Feed: TS-Si Research Service. TS-Si Reader Comments. Delicious: TS-Si News Service. Digg: TS-Si News Service.
Pinterest.
StumbleUpon. Facebook: TS-Si News Service.
GooglePlus: TS-Si News Service.
Twitter: Follow TS-Si News Service.
Leave a comment.
xkcd
Campaigns


is dedicated to the acceptance, medical
treatment, and legal
protection of individuals correcting the misalignment
of their brains and their anatomical sex, while supporting their transition
into society as hormonally reconstituted and surgically corrected citizens.
Generation of anti-trenbolone monoclonal antibody and establishment of an indirect competitive enzyme-linked immunosorbent assay for detection of trenbolone in animal tissues, feed and urine. Print E-mail
Resources - Abstracts
TS-Si Research Service   
Wednesday, 15 December 2010 15:28

Generation of anti-trenbolone monoclonal antibody and establishment of an indirect competitive enzyme-linked immunosorbent assay for detection of trenbolone in animal tissues, feed and urine.

Talanta. 2011 Jan 15;83(3):732-737

Authors: Zhang Y, He F, Wan Y, Meng M, Xu J, Yi J, Wang Y, Feng C, Wang S, Xi R

Trenbolone (TRE) is a steroid used by veterinarians on livestock to increase appetite and body weight. The use of TRE has been restricted because of its harmful side effect for consumers. To effectively control TRE residue in food and food product, a rapid and convenient immunoassay was developed by preparing an anti-TRE monoclonal antibody. The immunogen and coating antigen were prepared by coupling TRE hapten with carrier proteins via 1-ethyl-3-(dimethylaminopropyl)carbodiimide hydrochloride (EDC) method. The optimized method gave an average IC(50) value of 0.323ngmL(-1) towards TRE and an average detection limit (LOD) of 0.06ngmL(-1), which is much lower than the maximum residue levels (2.0ngg(-1)) accepted by the Joint FAO/WHO Expert Committee on Food Additives (JECFA). The specificity of the antibody was evaluated by measuring cross-reactivity of six structurally related compounds, including 19-nortestosterone (9.7%), testosterone (0.13%), methyltestosterone (<0.01%), methandrostenolone (<0.01%), (+)-dehydroisoandrosterone (<0.001%) and β-estradiol (<0.001%). The recovery rates of the test in detection of TRE-fortified animal tissue, urine and animal feed samples were in the range of 81.3-89.4%, while the intra- and inter-assay coefficients of variation were less than 12.0%.

PMID: 21147313 [PubMed - as supplied by publisher]

TS-Si Research ServiceThe TS-Si Research Service consolidates information on research initiatives and findings relevant to the misalignment of brains and anatomical sex. The service tracks key scientific and medical developments from early consideration of research opportunities and published findings through practical application in clinical settings.

Researchers and students from qualifying institutions regularly receive special emailings from TS-Si that consist of abstracts and other materials that support their interest areas.


Read Full Article
Comments (1)Add Comment

Write comment
smaller | bigger

busy
Last Updated on Wednesday, 15 December 2010 15:28